Predicting harvest time is difficult, so winemakers
and growers go into their vineyards and start taking "sugar" samples
several weeks before the expected harvest time. New samples are then taken
every few days and the data is often plotted in graphical form.
Variations are Large
Depending on weather conditions, bloom can extend over many days. Later in
the season, clusters from early blooming flowers are more mature and contain
more sugar than clusters from late blooming flowers. Differences of several
Brix can occur from cluster to cluster, and these differences make sugar testing
difficult. Grapes from a single cluster contain different amounts of sugar.
In general, grapes high on the cluster contain more sugar than grapes taken
from the bottom of the cluster. Grapes taken from clusters receiving the most
sun tend to contain the most sugar, and grapes taken from clusters growing
back under the foliage contain less sugar. There can be significant differences
in the sugar content of grapes from vines growing in different parts of a
vineyard. These vine to vine variations depend upon soil conditions, water
application, sun orientation, wind and many other factors. A two Brix variation
over a five acre vineyard block is often seen.
Large Sample Needed
A large number of grapes must be sampled in order to obtain reasonably accurate
results because of these large variations. A sample consisting of 100 individual
berries is considered the minimum size sample for a small vineyard. Large
operations often collect 500 to 1000 berry samples. Most winemakers consider
a few hundred berries to be an adequate sample size. Uniform Collection Necessary
Collecting sample grapes in a consistent way and from all parts of the vineyard
is important for accurate results. For example, a large and uniform sampling
of the entire vineyard would be collected if two grapes were picked from each
vine in a vineyard containing 100 vines. Alternatively, taking one grape from
every fourth vine would produce a uniform sample of 250 grapes in a vineyard
containing 1000 vines. The most important consideration is to attempt to collect
a reasonably large sized sample from the entire block that will be picked.
Collection Procedure
The following procedure has produced good results in the past, but any collection
method that meets the above objectives should produce satisfactory results.
- Use a 1 quart size, heavy weight, zip-seal, baggy
to hold the sample grapes.
- Pick one or two grapes from each vine (or every
other vine or every 5th, etc.) in order to collect 100 to 300 grapes. Be
sure to sample the entire vineyard block in a uniform way.
- Pick the sample berries from the bottom of the
grape clusters (watch out for bees).
- Pick the sample grapes from clusters that are growing
under the canopy in the shade.
- When finished, seal the baggy and keep it cool
until the measurements are made.
Sugar Measuring Instruments
The sugar content of the sample grapes can be measured using either a Brix
hydrometer or a refractometer. Both instruments are usually calibrated at
68 degrees and the accuracy of either instrument is temperature dependent.
However, some refractometers are temperature compensated and the compensation
reduces the temperature error considerably.
A refractometer can accurately measure
the sugar content of a drop of juice. A good temperature compensated instrument
will cost about $250 and it can be read directly to 0.2 Brix. A non-compensated
refractometer will cost about $100. But, the temperature error can be large
and must be taken into account when using a non-compensated instrument. The
major advantage to a refractometer is its ability to quickly measure a very
small size sample.
A short-range (16 to 25 Brix) hydrometer
floated in a small cylinder requires 100 to 200 milliliters of juice. It will
cost about $25 and it can be read to 0.1 Brix. The major advantage of a hydrometer
is its low cost.
Readings from a good hydrometer are more
precise than those from a hand held refractometer. But, the hydrometer must
be used at its calibration temperature or a temperature correction must be
applied to the reading. A simple way of making an accurate measurement is
to make sure both the grapes and the measurement instrument are at or near
the calibration temperature. Then, no temperature correction is needed.
| TEMPERATURE |
CORRECTION |
| 56 |
-0.38 |
| 58 |
-0.32 |
| 60 |
-0.26 |
| 62 |
0.20 |
| 64 |
-0.14 |
| 66 |
-0.08 |
| 68 |
0.0 |
| 70 |
+0.07 |
| 72 |
+0.14 |
| 74 |
+0.22 |
| 76 |
+0.30 |
| 78 |
+0.38 |
| 80 |
+0.46 |
| 82 |
+0.54 |
| 84 |
+0.62 |
| 86 |
+0.71 |
| 88 |
+0.80 |
Sugar Measurement Procedure
The following measurement procedure assumes the sugar measurement is made
with a Brix hydrometer. However, the procedure works equally well with a refractometer.
- Remove the air from baggy, seal it tightly, lay
on a smooth surface and use a flat-bottomed glass tumbler to lightly crush
the grapes in the baggy. If you crush to hard, the seeds will puncture the
baggy and cause leaks.
- Squeeze the mass of grapes in the baggy several
times with your right hand.
- Unseal the baggy, hold the lip of the baggy over
the hydrometer cylinder with your left hand and carefully squeeze the juice
out with your right hand. With a little practice you can keep the seeds,
skins and pulp in the baggy.
- When enough juice has been collected, carefully
lower the hydrometer into the cylinder.
- Wait a minute or two to let the hydrometer settle,
then tap the cylinder a few times to make sure the hydrometer is not "stuck"
to the side of the cylinder.
- Read the hydrometer and record the value.
- Remove the hydrometer from the sample, measure
the sample temperature with a thermometer and record the value.
- Use a hydrometer correction chart and apply the
appropriate temperature correction to the measured value.
Summary
Grape to grape, cluster to cluster and vine to vine variations in sugar content
can amount to several Brix. Consequently, a large sample (100 or more berries)
is necessary to obtain accurate results. Obtaining a uniform sample from the
vines that will be picked is important. If the intent is to pick the first
three rows, then the first three rows should be sampled. If the whole block
will be picked, then the whole block should be sampled. A temperature correction
will usually be necessary when measuring sugar with a hydrometer or a non-compensated
refractometer. |